Expertise > Technology Platforms > SmartPReP®2 APC+™
SmartPReP®2 APC+™
Tradition. Innovation. Leadership. When Harvest Technologies introduced the first SmartPReP Platelet Concentrate System, the use of autologous biomaterials to naturally stimulate the healing process was a relatively obscure practice. Today it is becoming standard-of-care.
The original SmartPReP system was the first and only system specifically designed for the rapid preparation of autologous platelet concentrate enriched with growth factors (APC+™). SmartPReP, for the first time, made the benefits of bioactive proteins practical in both the hospital and private practice office settings.
Harvest continues this tradition with the introduction of the SmartPReP 2. The SmarPReP 2 redefines platelet concentrate systems. The new system simultaneously delivers speed, performance, dependable results, and increased confidence by eliminating the guesswork and variability associated with other systems. SmartPReP 2's latest innovations will further expand and enhance the use of autologous bioactive proteins as well as help optimize the conditions for healing.
Overview
Platelets concentrated with the SmartPReP Platelet Concentrate System:
- Have characteristics similar to the requirements of the American Association of Blood Banks for transfusable platelets
- Release bioactive signal proteins and growth factors that remain active for up to 7 days
- Were concentrated significantly higher than other so-called “PRP” systems
Met or exceeded the 4 to 5 fold increase above the baseline needed to enhance wound healing
Predictability
The SmartPReP 2 sets a new standard for producing autologous platelet concentrate enriched with growth factors (APC+). The SmartPReP 2 redefines platelet concentrate systems:
- Technology: A revolutionary, self-calibrating, floating shelf technology automatically optimizes platelet recovery for every patient
- Flexibility: The system can process as little as 20 cc of whole blood for smaller applications in additional to larger volumes when needed
- Speed: Produces autologous platelet concentrate in a fraction of the time; less than 15 minutes
Confidence: The SmartPReP system is the first system FDA cleared for the preparation of APC+ which may help improve the handling characteristics of graft material, facilitate fixation of graft material to the surgical site, and help optimize conditions for healing.
Reliability
The SmartPReP 2 simultaneously delivers speed, performance, dependable results and increased confidence by eliminating the guesswork associated with other systems:
- Automation: Unique automated dual-spin and decanting process coupled with self-calibrating disposables are significantly easier to use than any of the more complex, time consuming, operator dependent systems
- Consistency: The floating shelf technology ensures optimal results independent of patient hematocrit, blood volume processed, or operator
- Simplicity: SmartPReP 2's use of state-of-the-art sensors and controls coupled with "Smart" disposables maximize platelet recovery while eliminating operator interaction
Simple Logistics: Eliminates delicate product weighing or multiple manipulations of blood bags or tests tubes. Eliminates schedule of specialized or dedicated technicians.
Hardware
Hardware system for the preparation of autologous platelet concentrate enriched with growth factors.
SMP-2: SmartPReP 2 Platelet Concentrate System 110V-50/60Hz.
SMP-2i: SmartPReP 2 Platelet Concentrate System 240V-50-60Hz
WS-2: SmartPReP2 APC+ Workstation
BW-60: Reusable Counter Balance Weight for SmartPReP 2 Designed for use with the APC-60 as the counter balance weight. 1/each.
BW-20: Reusable Counter Balance Weight for SmartPReP 2 Designed for use with the APC-20 as the counter balance weight. 1/each.
Process Disposables
We have taken the hassle out of concentrating growth factors and making PRP. Instead of trying to force one disposable to cover all surgical needs like other systems, Harvest offers three different procedure packs based on your needs. Consequently, you only pay for the product you need for your specific application.
Both our APC+ series and PRP series procedure packs
- Sold in 3 different configurations
- 20 ml blood draw provides 3 ml APC+ for small applications
- 60 ml blood draw provides 10 ml of APC+ for medium applications
- 120 ml blood draw provides 20 ml of APC+ for large applications
- Yield concentrated platelets in less than 15 minutes no matter what blood volume processed or procedure pack used
- Provide a platelet rich plasma product with at least a 4-5x platelet increase above baseline
- Automatically provide both platelet rich plasma and platelet poor plasma
- Provide all the components needed to make platelet rich plasma in one convenient kit
SmartPReP 2 APC+ series
Process disposables for the preparation of APC+ and Platelet Poor Plasma.
The APC-20i / APC-60i / APC-120i products do not include IV Site Prep Kit and are latex free.
APC-20 / APC-20i: APC+ Procedure Pack for SmartPReP 2
Includes components for 3ml APC+. 6/case. The APC-20 autologous platelet concentrate tray pack contains all the components needed for APC+ in one convenient kit. The APC-20 is designed to process 20cc of whole blood, which produces approximately 3 ml of APC+. (The APC-20 requires the use of a BW-20 counter-balance weight.)
Blood Draw Kit:
- 19 g IV Fistula
- 20 ml Blood Draw Syringe Assembly
- 3 ml Anticoagulant Syringe Assembly
- ACD-A 30 ml Anticoagulant, USP
Blood Process Kit:
- 20 ml Process Disposable (PD)
- 20 ml Plasma Syringe with Blunt Cannula and Spacer (1)
- 10 ml Platelet Concentrate Syringe with Cannula (1)
- 10 ml Syringe (Spare)
- Blunt Plastic Cannula (1)
- Color Coded Sterile Plastic Cups (3)
APC-60 / APC-60i: APC+ Procedure Pack for SmartPReP 2
Includes components for 5-10 ml APC+. 3/case.
The APC-60 autologous platelet concentrate tray pack contains all the components needed for APC+ in one convenient kit. The APC-60 is designed to process 55 ml of whole blood, which produces approximately 5-10 ml of APC+. (The APC-60 requires the use of a BW-60 counter-balance weight.)
Blood Draw Kit:
- I.V. Site Prep Kit
- 19 g IV Fistula
- 60 ml Blood Draw Syringe Assembly
- 3 ml Anticoagulant Syringe Assembly
- ACD-A 30 ml Anticoagulant, USP
Blood Processing Kit:
- 60 ml Process Disposable (PD)
- 30 ml Plasma Syringe with Blunt Cannula and 2 Spacers (1)
- 20 ml Platelet Concentrate Syringe with Blunt Cannula (1)
- 10 ml Syringe (Spare)
- Blunt Plastic Cannula (1)
- Color Coded Sterile Plastic Cups (3)
APC-120 / APC-120i: APC+ Procedure Pack for SmartPReP 2
Includes components for 10-20 ml APC+. 2/case.
The APC-120 autologous platelet concentrate tray pack contains all the components needed for APC+ in one convenient kit. The APC-120 is designed to process 110 ml of whole blood, which produces approximately 10-20 ml of APC+.
Blood Draw Kit:
- IV Site Prep Kit
- 19 g IV Fistula
- 60 ml Blood Draw Syringe Assembly (2)
- 5 ml Anticoagulant Syringe Assembly
- ACD-A 30 ml Anticoagulant, USP
Blood Process Kit:
- 60 ml Process Disposable (PD) (2)
- 30 ml Plasma Syringes with Blunt Cannula and 2 Spacers (2)
- 20 ml Platelet Concentrate Syringe with Blunt Cannula (2)
- 10 ml Syringe (Spare)
- Blunt Plastic Cannula (1)
- Color Coded Sterile Plastic Cups (3)
|
|
SmartPReP 1
Process disposables for the preparation of Platelet Rich Plasma (PRP) and Platelet Poor Plasma (PPP) from whole blood.
PRP-20 / PRP-20i: PRP Procedure Pack for SmartPReP 1 Includes components for 3ml PRP. 6/case. The PRP-20 platelet rich plasma tray pack contains all the components needed for PRP in one convenient kit. The PRP-20 is designed to process 20cc of whole blood, which produces approximately 3 ml of PRP. (The PRP-20 requires the use of a PDR-20 counter-balance weight.)
Blood Draw Kit:
- 19 g IV Fistula
- 20 ml Blood Draw Syringe Assembly
- 3 ml Anticoagulant Syringe Assembly
- ACD-A 30 ml Anticoagulant, USP
Blood Process Kit:
- 20 ml Process Disposable (PD)
- 20 ml Plasma Syringe with Blunt Cannula and Spacer (1)
- 10 ml Platelet Concentrate Syringe with Cannula (1)
- 10 ml Syringe (Spare)
- Blunt Plastic Cannula (1)
- Color Coded Sterile Plastic Cups (3)
|
PRP-1: The PRP-1 platelet rich plasma tray pack contains all the components needed for PRP in one convenient kit. The PRP-1 is designed to process 50cc of whole blood, which produces approximately 3-10cc of PRP. (The PRP-1 requires the use of a PDR-1 counter-balance weight.) |
For Blood Draw:
- 19 g IV Fistula
- 20 ml Blood Draw Syringe Assembly
- 3 ml Anticoagulant Syringe Assembly
- ACD-A 30 ml Anticoagulant, USP
For Process:
- Process Disposable (PD)
- 30 ml Syringe (2)
- Blunt Needles (2)
PRP-2:
The PRP-2 platelet rich plasma tray pack contains all the components needed for PRP in one convenient kit. The PRP-2 pack is designed to process 100cc of whole blood, which produces approximately 10-20cc of PRP. |
For Blood Draw:
- 17g Vein Access Needle Kit
- 60 ml Syringe (2)
- 5 ml Syringe
- 16g Needle (2)
- Needle-less Syringe Cannula (2)
- ACD-A 50 ml
For Process:
- Process Disposable (PD)(2)
- 30 ml Syringe (4)
- Blunt Needles (4)
SmartJet™ Applicator Kits
The SmartJet applicator kits eliminate the guesswork when applying platelet concentrate. The SmartJet applicators simultaneous and precisely deliver platelet concentrate and thrombin to the surgical site. The kits assemble in seconds and require only single-handed operation for controlled application.
LK/2 Liquid Applicator Kit for precision deliver of bioactive proteins
- 1 ml Activator Syringe
- 10 ml APC+ Syringe
- Handle
- Stabilizer Clip
- Liquid Applicator Tip
|
|
|
|
|
|
|
Chennai, November 26, 2007
LifeCell, the pioneers in cord blood stem cell banking and research, jointly with Sri Ramachandra University (SRU), has launched its first exclusive Stem Cell Center for stem cell transplants and research, TRICell. Former President of India, Dr. A.P.J. Abdul Kalam, will formally inaugurate the Center on November 28, 2007.
Read more
|
Help line
+91 - 44 - 99403 14707
Phone
E-mail
Website
:
:
:
91 - 44 - 4284 9346
91 - 44 - 4284 9554
info@tricell.in
http://www.tricell.in
|
|
Dr. A.P.J. Abdul Kalam has inaugurated TRICell - Stem Cell Center on 28th November 2007, Wednesday at 4:00pm |
|